63 and 225 kV substations
Protection relay testing
Differential protection and on-load tap changers. Testing carried out with Volt Expertise.
Service
Relay configuration from the protection plan, injection testing, testing of on-load tap changers and substation automation, test reports.
Testing verifies the complete chain, from the measured quantity to the opening of the circuit-breaker. We check that the settings are actually loaded in the relay, that the CTs are wired the right way round and that the trip command reaches the coil.
We work on all generations of relays, electromechanical, static and numerical. The ranges we encounter most often are Schneider Electric Sepam and Easergy P3, MiCOM, Siemens SIPROTEC 4 and 5, ABB / Hitachi Energy Relion (615, 620, 670 series) and SEL. Configuration is done with the manufacturers' software, from the settings schedule.
The functions tested are phase and earth overcurrent (50/51, 50N/51N), directional (67, 67N), transformer, busbar and line differential (87T, 87B, 87L), distance (21), voltage and frequency (27/59, 81), breaker failure (50BF), auto-recloser (79) and synchronism check (25). In digital substations, we also verify IEC 61850 (GOOSE) exchanges between devices.
The on-load tap changer (OLTC) is the only part of a transformer that switches under load. We test the tap changer and its drive: direction of operation, electrical and mechanical end stops, position indication and remote signalling, local and remote control, operation counter, the tap changer compartment's own protection.
We then test the voltage regulator, with the setpoint, deadband, first and second operation time delays, line drop compensation, undervoltage and overcurrent blocking, and parallel operation of several transformers (master / follower or minimum circulating current). A poorly set regulator hunts and operates constantly, which wears the tap changer.
We test source transfer and restoration, load shedding on frequency or load, auto-reclosing, intertripping between substations, interlocking and capacitor bank control. For power plants and storage, we also test the power plant controller (voltage, reactive power and cos φ control, power limitation) and its response to the network operator's setpoints.

Usual content of an offer for this type of assignment. The exact scope, deliverables and price are set in the quotation.
Settings schedule, diagrams, test sheets per function.
Files loaded, reviewed and compared with the schedule.
Injection, trip chains, tap changers and regulators, automation, according to the scope.
Results, deviations, punch-list items closed or still open.
Settings schedule, diagrams, test sheets per function.
Files loaded, reviewed, compared with the schedule.
Thresholds, times, curves, logic, trip chains.
Tap changers, regulators, automation, under real conditions where possible.
Results, deviations, punch-list items closed or still open.
63 and 225 kV substations
Differential protection and on-load tap changers. Testing carried out with Volt Expertise.
Industrial site
MV protection coordination and on-site check of the settings.
We can check the existing settings, but we recommend an up-to-date protection plan first.
Yes. Electromechanical and static relays can also be tested, with suitable methods. Their replacement is discussed in light of the results.
Throughout France, usually during plant shutdowns.
For a project, give us the voltage, power, location and deadline in a few lines.
Reply within 48 working hours.